Solenoid Valves » Direct Acting Valve

An electrically operated direct acting solenoid valve for the dispense of low pressure (maximum 0.2 bar) water or air. Available inline or right angled. Typically used in cold water drink dispensers, pressure relief, and pnuematic equipment.

 

Direct Acting Valve
Attributes
Name Value
Ambient Temperature 60 °C maximum
Liquid Temperature Water/ air 60 °C maximum
Pressure Range 0.2 maximum
Flow Regulation None
Operating Limits Continuous 100%, Tm 90 °C, Tu 25 °C, 3 minutes on 5 minutes off, Tm 90 °C, Tu 60 °C
Power Draw 6 VA
Rated Voltage 230V, 120V or 24V AC, 24V or 12V AC/DC
Coil Insulation Class F- 140 °C operating temperature
Frequency 50/60 Hz or DC
Terminals Two 6.35mm x 0.8 mm male tab terminals
Ports Inlet/Oulet 12mm x 12mm Smooth and 10mm x 10mm and 6mm x 6mm hose barb
Construction Polyamide body with Nitrile or EPDM diaphragm minimum burst pressure 65 bar
Approvals All major electro-technical and potable water standards ie: EN 60730-2-8, UL429, CSA C22.2 etc, BEAB, NSF and WRAS